中文Language Search
Home > Products > Environmental Simulation Units > Special Environmental Test Chamber > Rain test chamber
Environmental Simulation Units
< Back

Rain test chamber

Applications: 

The test chamber is mainly used to check whether the case and seal part of electronic and electrical products can work well after water test or during the test period. It meets GB2423.382005, GB4208-93, IEC60529-2001 and other standards

Parameter: 

Model

YLX500

YLX010

Size H×W×Dcm

80×80×80

100×100×100

Water spray ring radius: 300mm (LX500) ,400mm (LX010), pipe diameter φ16mm

Water spray aperture: 0.4mm, aperture spacing: 50mm

Swing: 0°~±180° (theoretical value) adjustable

Adjustable speed turntable: 17 turn/min

Interior Chamber: SUS 304# stainless steel. External Chamber: Stove varnish or SUS304# brushed stainless steel

Nozzle flow: 0.07L/min (optional 0.6L/min)

Spray time: 09999min adjustable (10min, 30min, 60min)

Control System: PLC programming control system, touch screen Chinese interface

Protection: leakage, short circuit, phase loss, water shortage protection

Download PDF