中文Language Search
Home > Products > Light Simulation Units > Solutions of Solar Industry > UV aging room
Light Simulation Units
< Back

UV aging room

Specification: 

Standard: IEC61215/IEC61646
Irradiation Intensity Range: 150-250w/m2

Various irradiation range can be customized according to customer requirements;

Equipped with multiple temperature protection sensors to ensure the safe and stable operation of the system;

Touch-screen control interface

Model

GRO-SUV4030T-R

GRO-SUV4040T-R

GRO-SUV4050T-R

GRO-SUV4060T-R

Temperature/humidity of environment while using

+5+35/≤80%RH

Controller

GRO-800 control instrument integrated Siemens S7 programmable controller

Control Mode

Air volume can be continuously adjusted

Number of samples (Crystal silicon component 2000*1000mm)

6pcs

8pcs

10pcs

12pcs

Parameter

Irradiation Area (mm)

4000*3000

4000*4000

4000*5000

4000*6000

Irradiation Intensity

150-250 w/

Nonuniformity

±15%

Spectral Range

280-400nm

UVB/(UVA+UVB)

3-10%

Temperature Fluctuation

≤±2.0

Temperature Deviation 

≤±2 (No Load)

Sample Temperature Uniformity

≤±5

Sample Backside Temperature 

60±5

Interior Size

W(mm)

4400

4400

4400

4400

D(mm)

3400

4400

5400

5400

H(mm)

2000

2000

2000

2000

External Size

W(mm)

4800

4800

4800

6000

D(mm)

4200

5200

6200

5800

H(mm)

2400

2400

2400

2400

Exhaust Volume (m³)

≥25000

≥32000

≥40000

≥48000

Power Supply 

AC 380V 50Hz 3-phase+N+PE

Maximum Current (A)

80

100

120

140

Maximum Power (kw)

50

64

78

92

Standard Equipment                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              

● Viewing Window

● Sample Holder

● Ultraviolet Sensor

● Temperature Sensor

● Interior Lighting

● USB Port

● Cable Hole with Silicone Plug Φ80mmx1

Optional Equipment                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              

○ External Outlet 220V 10A

○ Electronic Load

○ Automatic Scanning System
○ LAN interface and remote-control software

Other non-standard configurations

*Performance index is measured at room temperature of +25°C; The sensor is at the air outlet of the air handling unit.


Download PDF